LT4000M Series Lineup

Specifications of PFXLM4201TADDC
(Modular Type DIO / Source Output Type)

Display Specifications

Type TFT Color LCD
Resolution (pixels) 320 x 240 (QVGA)
Active display area (W x H) 70.56 x 52.92 mm (2.78 x 2.08 in.)
Display Colors 65,536 colors
Backlight White LED
Non-exchangeable
LED ON / OFF control, adjustable screen saver activation time
Brightness adjustment 16 levels of adjustment available via touch panel in the configuration menu
Language Fonts *1 Japanese, ASCII, Chinese (Simplified), Chinese (Traditional), Korean, Cyrillic, Thai
Character sizes 8 x 8, 8 x 16, 16 x 16 and 32 x 32 pixel fonts
Font sizes Width can be expanded 1 to 8 times. Height can be expanded 1/2 and 1 to 8 times.
8 x 8 pixels 40 characters per row x 30 rows
8 x 16 pixels 40 characters per row x 15 rows
16 x 16 pixels 20 characters per row x 15 rows
32 x 32 pixels 10 characters per row x 7 rows
MemoryApplication memory *2 FLASH EPROM 16 MB
(includes screen editing program and extended logic program)
Logic program area FLASH EPROM 132 KB *3 (equivalent to 15,000 steps)
Font area FLASH EPROM 8 MB (when limit exceeded, uses application memory)
Data backup nvSRAM 128 KB (rechargeable lithium battery for data backup)
Variable area nvSRAM 64 KB (rechargeable lithium battery for data backup)
Touch PanelType Resistive Film (analog)
Lifetime 1 million touches or more
InterfaceSerial (COM1) RS-232C/RS485 x 1

RS-232C (Connector type: RJ45, Isolation: None, Maximum baud rate: 115,200 bps, Cable Type: Shielded, Cable Maximum length: 15 m (49 ft), 5 Vdc power supply for RS-232C: None)

RS-485 (Connector type: RJ45, Isolation: None, Maximum baud rate: 115,200 bps, Cable Type: Shielded, Cable Maximum length: 200 m (656 ft), Polarization: Setting is required via software when connecting Multiple LTs. Refer to the "GP-Pro EX Device/ PLC Manual" for the setting. 5 Vdc power supply for RS-485: None) *4
CANopen (master) CAN-CiA (ISO 11898-2:2002 Part 2), Connector: D-sub9 (pin)
Ethernet IEEE802.3 compliant Ethernet x 1

(Connector type: RJ45, Driver: 10 M half duplex (auto negotiation)/ 100 M full duplex (auto negotiation), Cable type: Shielded, Automatic cross-over detection: Yes)
USB (Type A) USB 2.0 (Type A) x 1
(Power Supply Voltage: 5Vdc +/-5%, Maximum Current Supplied: 500mA, Maximum Transmission Distance: 5m (16.4 ft.))
USB (Mini-B) USB 2.0 (Mini-B) x 1
ControlDIO(Source Type) 20 Points Standard Input (including 2 Points for Fast Input)
10 Points Standard Output, 2 Points for Fast Output
  1. Please refer to the GP-Pro EX Reference Manual for details on font types and character codes.
  2. Capacity available for user application.
  3. Up to 60,000 steps can be converted in software. However, this reduces application memory capacity (for screen data) by 1 MB.
  4. 2-wire connection is available for RS-485. When a Device/PLC supports 2-wire connection, 4 wires (RXD+, TXD+, RXD-, and TXD-) can be short-circuited to be 2 wires (RXD+ and TXD+ = D1, RXD- and TXD- = D0). For details on the connection, refer to the connection manual.

General Specifications

Supported Standards and Regulations
Rated Input Voltage 24 Vdc
Input Voltage Limits 20 to 28.8 Vd
Acceptable Voltage Drop 10 ms or less at 20.4 Vdc
Power Consumption 9 W or less
In-Rush Current 30 A or less at 28.8 Vdc
Voltage Endurance between power terminal and frame ground (FG) 500 Vdc for 1 minute
Insulation Resistance between power terminal and FG 10 MΩ or higher at 500 Vdc

Environmental Specifications

Standard compliance IEC 61131-2
Ambient operating temperature for the display and the rear moduleHorizontal installation 0 to 50°C (32 to 122°F)
Vertical installation 0 to 40°C (32 to 104°F)
Storage temperature - 20 to 60°C (- 4 to 140°F)
Storage altitude 0 to 10,000 m (0 to 32,808 ft)
Operating altitude 0 to 2,000 m (0 to 6,560 ft)
Surrounding Air and Strage Humidity 5 to 85% w/o condensation (non-condensing, wet bulb temperature 39°C (102.2°F) or less)
Degree of pollutionIEC60664 2
Degree of protectionIEC61131-2 IP20 with protective covers in place
Corrosive gases Free of corrosive gases
Dust ≤0.1 mg/m3 (10-7 oz/ft3) (non-conductive levels)
Atmospheric pressure (Operating Altitude) 800 to 1,114 hPa (2000 m (6,561 ft) or lower)
Vibration resistanceMounted on a DIN rail 3.5 mm (0.138 in.) fixed amplitude from 5 to 8.4 Hz
9.8 m/s2 (1 gn) fixed acceleration from 8.4 to 150 Hz
Mounted on a panel 3.5 mm (0.138 in.) fixed amplitude from 5 to 8.6 Hz
9.8 m/s2 (1 gn) fixed acceleration from 8.6 to 150 Hz
Mechanical shock resistanceMounted on a DIN rail 147 m/s2 (15 gn) for a duration of 11 ms
Mounted on a panel 147 m/s2 (15 gn) for a duration of 6 ms
Electrostatic dischargeIEC/EN 61000-4-2 8 kV (air discharge)
6 kV (contact discharge)
Rediated radio frequency electromagnetic fieldsIEC/EN 61000-4-3 10 V/m (80 MHz to 3 GHz)
Fast transients / Burst noiseIEC/EN 61000-4-4 Power lines: 2 kV
Digital I/O: 1 kV
Relay outputs: 2 kV
Ethernet line: 1 kV
COM line: 1 kV
CAN line: 1 kV
Surge immunityIEC/EN 61000-4-5 Power supply: CM: 1 kV; DM: 0.5 kV
Digital I/O: CM: 1 kV; DM: 0.5 kV
Shielded cable: 1 kV
CM = line-earth
DM = line-line
Conducted disturbances induced by radio-frequency fieldsIEC/EN 61000-4-6 10 Veff (0.15 to 80 MHz)
Mains terminal dusturbance voltageEN 55011 (IEC/CISPR11) 150 to 500 kHz, quasi peak 79 dBμV
500 kHz to 30 MHz, quasi peak 73 dBμV
Electric field strengthEN 55011 (IEC/CISPR11) 30 to 230 MHz, quasi peak 10 m @40 dBμV/m
230 MHz to 1 GHz, quasi peak 10 m @47 dBμV/m
Vibration immunity (operating) IEC 61131-2
Protection structure NEMA TYPE 4X (indoors, with panel embedded)
Protection (front module) IP65f - (IEC 60529)
Protection (rear module) IP 20 - (IEC 60529)
Shock immunity (operating) IEC 61131-2
15 gn 11 ms
Cooling method Natural air circulation
Weight 496 g (17.49 oz)
Color Front module: PT404 Rear module: RAL 7032
Material Front module: PC/PBT
Rear module: PC/PBT

Digital Inputs

Digital Input Characteristics

Rated Current 5 mA
Inrush ValuesVoltage 30 Vdc
Current 6.29 mA max.
Input impedance 4.9 kΩ
Input type Sink/Source
Rated voltage 24 Vdc
Maximum Allowable Voltage 28.8 Vdc
Input limit valuesON Voltage 15 Vdc or more (15 to 28.8 Vdc)
OFF Voltage 5 Vdc or less (0 to 5 Vdc)
ON Current 2.5 mA or more
OFF Current 1.0 mA or less
IsolationMethod Photocoupler Isolation
Between internal logic 500 Vdc
Filtering 0.5 ms to 30.0 ms
IEC61131-2 edition 3 type Type 1
Compatibility Supports 2 wire and 3 wire sensors
Cable type and length Shielded: Maximum 100 m (328 ft)
Non-shielded: 50 m (164 ft)
Terminal blocks Type: 3.5 mm (0.137 in.) pitch
Terminal blocks are removable
Input paralleling No
3_dio_input.gif

* I0 and I1 are Fast input terminals and can be also used as a Standard input. For specifications, see the specifications of Fast Input.

High Speed Counter Input Characteristics

Rated CurrentVoltage 24 Vdc
Current 7.83 mA
Inrush valuesVoltage 30 Vdc
Current 9.99 mA
Input impedance 3.2 kΩ
Input type Sink/Source
Rated voltage 24 Vdc
Maximum Allowable Voltage 28.8 Vdc
Input limit valuesON Voltage 15 Vdc or more
OFF Voltage 5 Vdc or less
ON Current 5 mA or more
OFF Current 1.5 mA or less

Isolation

Method Photo coupler Isolation
Between channels logic 500 Vdc
Filtering None, 4 μs, 40 μs
IEC61131-2 edition 3 type Type 1
Compatibility Supports 2 wire and 3 wire sensors
CableType Shielded
Length Maximum 10 m (33 ft)
Terminal blocks Type: 3.5 mm (0.137 in.) pitch
Terminal blocks are removable
Maximum frequency · 100 kHz is the maximum frequency for Single-phase
· 50 kHz is the maximum frequency for 2-phase
· Duty Rate: 45 to 55%
Phase Counting Mode · Single phase
· 2 Phase x2
· 2 Phase x4
· 2 Phase x2 Reverse
· 2 Phase x4 Reverse
Response timeMarker 1 ms
Preload 1 ms
Prestrobet 1 ms
Synchronize output 2 ms
Min. Pulse Width(Pulse input) Counter:

Pulse Catch
Input signal ON width

Input paralleling No
3_dio_input_hsc.gif

Digital Outputs

Transistor Output Characteristics

Rated Voltage 24Vdc
Output range 19.2 to 28.8 Vdc
Output type Source
Rated current 0.3 A/point, 3.0 A/common
Residual voltage 1.5 Vdc or less for I= 0.1A
Delay

Off to on (0.3 A load): 1.1ms
On to off (0.3 A load): 2ms
NOTE: The delay is not including the cable delay.

IsolationMethod Photocoupler Isolation
Between internal logic 500 Vdc
Minimum resistor load 80 Ω at 24 Vdc
Cable length Non-shielded: 150 m (492 ft)
Protection against short circuit No
Terminal blocks

Type: 3.5 mm (0.137 in.) pitch
Terminal blocks are removable

NOTE: Refer to LT4201TM/4301TM Hardware Manual about Protecting Outputs from Inductive Load Damage for additional information on this topic.
4_dio_output.gif
(1) When connecting as power surges

* To use 3.0A common current, connect to A3 and A4 for V1+. (B3 and B4 for V1-)


Caution: Q0 and Q1 circuits are push-pull circuits. The following is the operation of the push-pull circuit at the Sink Output and the Source Output.
Sink Output: +24(V) is output to terminal Q0, Q1 when the logic for Q0, Q1 is off
Source Output: 0(V) is output to terminal Q0, Q1 when the logic for Q0, Q1 is off

Standard Output terminals Q2 or later are common open collector outputs.
Do not connect Fast Output terminals Q0, Q1 and Standard Output terminals Q2 or later. It will short.
note1.gif

If you add a manual circuit to terminal Q0, Q1, isolate the manual circuit and terminal Q0, Q1 with a relay. Without isolation, it will short.
note2.gif

Pulse Output/PWM Output/High-speed Counter (Synchronize Output) Characteristics

Output type Source
Rated voltage 24 Vdc
Power supply input range 19.2 to 28.8 Vdc
Power supply reverse protection Yes
Pulse Output/PWM output current 50 mA/point, 100 mA/common
Response time for original input

2 ms

Isolation resistanceBetween fast outputs and internal logic 10 MΩ or more
Between power supply port and protective earth ground (PE) = 500 Vdc 10 MΩ or more
Residual voltagefor I = 0, 1 A 1.5 Vdc or less
Delay Off to on (50 mA load): 1.1ms
On to off (50 mA load): 1.1ms
NOTE: The delay is not including the cable delay.
Minimum load impedance 80 Ω
Maximum Pulse output frequency 50 KHz
Maximum PWM output frequency

65 kHz

Accuracy Pulse Output/ PWM OutputFrequency Accuracy Duty
10 to 1000 Hz 1% 1 to 99%
1.001 to 20 kHz 5% 5 to 95%
20.001 to 45 kHz 10% 10 to 90%
45.001 to 65 kHz 15% 15 to 85%
Duty rate range 1 to 99%
CableType

Shielded, including 24 Vdc power supply

Length Maximum 5 m (16 ft)
Terminal blocks

Type: 3.5 mm (0.137 in.) pitch
Terminal blocks are removable

NOTE: When using the acceleration/deceleration pulse output, there is a 1% maximum error for the frequency.
5_dio_output.gif

Caution: Q0 and Q1 circuits are push-pull circuits. The following is the operation of the push-pull circuit at the Sink Output and the Source Output.
Sink Output: +24(V) is output to terminal Q0, Q1 when the logic for Q0, Q1 is off
Source Output: 0(V) is output to terminal Q0, Q1 when the logic for Q0, Q1 is off

Standard Output terminals Q2 or later are common open collector outputs.
Do not connect Fast Output terminals Q0, Q1 and Standard Output terminals Q2 or later. It will short.
note1.gif

If you add a manual circuit to terminal Q0, Q1, isolate the manual circuit and terminal Q0, Q1 with a relay. Without isolation, it will short.
note2.gif

Terminal Blocks

Pin ArrangementGroupPinSignal NameGroupPinSignal Name
dio_terminal_block_1.gif Fast Output A1 V0+ Fast Output B1 V0-
A2 Q1 B2 Q0
Standard Output A3 V1+ Standard Output B3 V1-
A4 V1+ B4 V1-
A5 Q3 B5 Q2
A6 Q5 B6 Q4

 

Pin ArrangementGroupPinSignal NameGroupPinSignal Name
dio_terminal_block_2.gif Standard Output C1 Q7 Standard Output D1 Q6
C2 Q9 D2 Q8
C3 Q11 D3 Q10
Fast Input/Standard Input C4 I0 Fast Input/Standard Input D4 IC0
C5 I1 Standard Input D5 I2
Standard Input C6 I3 D6 IC1
C7 I5 D7 I4
C8 I7 D8 I6
C9 I9 D9 I8
C10 IC2 D10 IC2
C11 I11 D11 I10
C12 I13 D12 I12
C13 I15 D13 I14
C14 I17 D14 I16
C15 I19 D15 I18

External Dimensions

lt4201_dimension.gif

Panel Cut-out

panel_cut.gif

* If rotating torque acted on a display module is 2.5 N.m (22.12 in-lb) or more, use an anti-rotation tee which is supplied with a LT unit. The anti-rotation tee supports up to 6 N.m (53.10 in-lb).